How To fix the 500 Error using Favorite Reports in the SCOM web console.

22 May

First mention this is a non official solution.

The Problem

You have installed SCOM 2012 Sp1 UR2 and have implemented the scom webconsole and reporting service to be running under HTTPS mode. You have created using the native scom console a favorite report and now when you try to open this favorite report in the scom webconsole you get a error 500.

image

image

Analyzing

To see the real error we have to do some web.config changes. So open the web.config file on this location: C:\Program Files\System Center 2012\Operations Manager\WebConsole\MonitoringView

Now we enable the SCOM error logging

image

And to get it displayed on the user page we do

image

Now when you run the favorite report again we get in the webconsole  the real error

image

Okay looks like the reportviewer web component binary dll can’t be found. Hmm but wait wasn’t this a prereq at installation time. So I checked if the 2010 ReportViewer components where installed and yes it was and the dlls where also spotted in the assembly cache. It looks like the webconsole has problems finding the correct version of the Microsoft.ReportViewer.WebForms.dll in the assembly cache.

The Quick non Official Solution

Copy the missing dlls to the correct directory will force the web runtime to first look in this directory for the dlls and then go to the assembly cache. So that’s what i did.

Copy the Microsoft.ReportViewer.WebForms.dll file from the assembly cache to path : C:\Program Files\System Center 2012\Operations Manager\WebConsole\MonitoringView\bin

Come on give me some script to do that ! Okay open PowerShell as admin and run

Copy-Item c:\Windows\assembly\GAC_MSIL\Microsoft.ReportViewer.WebForms\10.0.0.0*\*.dll “C:\Program Files\System Center 2012\Operations Manager\WebConsole\MonitoringView\bin”

And now you try to run the favorite report again in the webconsole …

image

… and Yes its working!

The End.

For me this looks  like a bug and I will address this to Microsoft.

Happy Scomming!

Michel Kamp

Advertisements

SCOM Console Hidden Feature ??

21 May

A really short post. A member of a NOC operations team reported a problem with his SCOM console.

The Problem.

Using the operations native console and opening a windows computer state view resulted in gray computer targets.

image

Analyze

Normally when for example the computer targets are gray you know it’s a gent connectivity problem or the MS health service is stalled / crashed.  But this time non of this was true. Looking at the agents and MS states its was all green and okay.

The solution

First the root cause was assumed to be the computer of the NOC operator. Yes I have rebooted it twice and I have installed all the patches was the first response Knipogende emoticon  . But however I am running Windows 8. Okay .. could this be the case ?… After a while of figuring out what could be the problem we detected that on other NOC computers the problem was also reproduced. And yes now we had found the problem .. And what do you think ? If you have a target state view (for example the windows computer view) and you personalize this view and remove the State column you will facing the problem above. So we added the State Column again and the problem was fixed.

image

The End

Of course you can ask you’re self why remove the state column it’s a very important one. Lets say the most important one in a state view…. I have ask it my self’s but I think it was a human error by mistake and not noticed earlier… But the question remains this still looks like a bug in the SCOM console.. What do you think ?

Happy Scomming